Fast Storage Server
- Forwards fast raw devices using iSER protocol
- Read-ahead of the raid should be adjusted for the optimum performance
blockdev --setra 65536 /dev/sd#
- Package tgt
- No iSER support in OpenSuSE RPMS
- Recompile adding ISCSI_RDMA=1 parameter to make command
- /etc/tgt/targets.conf
default-driver iser <target iqn.ipepdvcompute1.fast> <direct-store /dev/disk/by-partlabel/fast> bs-type aio MaxRecvDataSegmentLength 2097152 MaxXmitDataSegmentLength 2097152 FirstBurstLength 8388608 MaxBurstLength 8388608 block-size 512 write-cache off </direct-strore> </target>
Camera Computer
- openiscsi package, iscsid should be started on boot
- Server node configuration
iscsi_discovery 192.168.11.1 -t iser -f iscsi_discovery 192.168.11.3 -t iser -f
- It will populate 2 extra /dev/sd? nodes
- Create softraid 0 for optimal performance
mdadm --create /dev/md3 -n 2 -l 0 /dev/disk/by-path/pci-0000\:06\:00.0-ip-192.168.11.1\:3260-iscsi-iqn.ipepdvcompute1.fast-lun-1 /dev/disk/by-path/pci-0000\:06\:00.0-ip-192.168.11.3\:3260-iscsi-iqn.ipekatrinadei.fast-lun-1
- Format it with XFS
mkfs -t xfs /dev/md3
- fstab entry
/dev/md3 /mnt/server xfs noauto,noatime,allocsize=1GiB,largeio,swalloc,delaylog,nobarrier 0 0
Glusterfs Cluster
- 20TB partitions are formatted using XFS and mounted with default options into /mnt/raid
- /mnt/raid/gluster/meta - folder with cluster metadata
- /mnt/raid/gluster/storage - storage
- /etc/glusterfs/glusterd.vol on the storage nodes
volume management type mgmt/glusterd option working-directory /mnt/raid/gluster/meta option transport-type socket,rdma option transport.rdma.bind-address 192.168.11.3 option transport.rdma.listen-port 24008 option transport.socket.keepalive-time 10 option transport.socket.keepalive-interval 2 option transport.socket.read-fail-log off end-volume
- /etc/glusterfs/glusterd.vol on the other nodes
volume management type mgmt/glusterd option working-directory /var/lib/glusterd option transport-type socket,rdma option transport.rdma.bind-address 192.168.11.2 option transport.rdma.listen-port 24008 option transport.socket.keepalive-time 10 option transport.socket.keepalive-interval 2 option transport.socket.read-fail-log off end-volume
- All nodes of cluster should be registered from the master node with
gluster peer probe 192.168.11.#
- Currently replicating storage is used, created with:
gluster volume create storage replica 2 transport rdma 192.168.11.1:/mnt/raid/gluster/storage 192.168.11.3:/mnt/raid/gluster/storage gluster volume start storage
- Mounted with following line in fstab
192.168.11.1:storage /pdv glusterfs defaults 0 0